Gas Turbine Filters

Gas turbines and compressors require air filters installed in supply air systems to provide superior protection of the blades against fouling, erosion, and corrosion to ensure optimal performance while guaranteeing low resistance to airflow (increased output) and extended service life (reduction of shut downs).

Our Gas Turbine Filters

Appropriate products include Medium and High Efficiency PocketMVMX and MINI Pleat filters as well as TFP cartridges

Lowest Pressure Drop: .42″ pressure drop at 600 cfm translates into significant increase in engine performance over competitive filters with .55-.60″ pressure drop.

Longest Filter Life: Depth loading media increases filter life by 2-4 times over the competition, which often face load, meaning the particles stick to the front surface and plug quicker.

Highest Efficiency: We offer the highest efficiency filters available for gas turbine intakes. That means fewer particles reach the turbine blades reducing your maintenance costs. Our 93% initial efficiency far surpass the competition.

Moisture Resistant: Synthetic non woven, depth loading media is hydro- phobic, meaning it resists moisture. Moisture causes the competitions filter media to swell which further increases the pressure drop, reducing output performance.

Overall Cost Effectiveness: Although the initial cost is higher, the pay back on these filters is significant due to all of the above factors. Longer life, Lower pressure drop, higher efficiency add up to overall cost savings.

Medium Gas Turbine Filters

F50T60GF55GF65
Rated Air Flow (cfm)2000200020002000
Average Dust Spot Efficiency (%)*506255**65**
Initial Efficiency on Particles >3 microns
(%)
64906792
Initial Resistance
(in. w.g.)
0.170.200.170.20
Max. Temperature (ºF)160,
peaks 200
160,
peaks 200
160,
peaks 200
160,
peaks 200
UL 900 ClassificationClass 2Class  2Class  2Class 2
Depth (in)26262626
Size Availability1/1, 5/6, 1/2,1/4 and
S 1/1 – 18″
1/1, 5/6, 1/2 and
S 1/1 – 18″
1/1, 5/6, 1/2 and
S 1/1 – 18″
1/1, 5/6, 1/2 and
S 1/1 – 18″

* According to ASHRAE 52.1 – 1992   ** Target Data

High Efficiency Pocket

MF90MF95T90T98
Rated Air Flow (cfm)2000200020002000
Average Dust Spot Efficiency (%)*97989498
Initial Efficiency on Particles >1 micron
(%)
98>99>95>99
Initial Resistance
(in. w.g.)
0.420.540.390.30
Burst Strength
(in. w.g.)
>12>12>12>12
Max. Temperature (ºF)160,
peaks 200
160,
peaks 200
160,
peaks 200
160,
peaks 200
UL 900 ClassificationClass 2Class  2Class  2Class 2
Depth (in)26262626
Size Availability1/1, 5/6, 1/2, 1/4 and
S 1/1 – 18″
1/1, 5/6,
1/2, 1/4
1/1, 1/21/1, 5/6, 1/2, 1/4

* According to ASHRAE 52.1 – 1992

MV

MV65MV75MV85MV95
Rated Air Flow (cfm)2000200020002000
Average Dust Spot Efficiency (%)*65758595
Initial Efficiency on Particles >1 micron
(%)
>69>80>91>94
Initial Resistance
(in. w.g.)
0.260.270.290.33
Max. Temperature
(ºF)
160,
peaks 175
160,
peaks 175
160,
peaks 175
160,
peaks 175
UL 900 ClassificationClass 2Class 2Class 2Class 2
Depth (in)11.511.511.511.5
Size Availability1/1, 5/6, 5/5,1/21/1, 5/6, 5/5,1/21/1, 5/6, 5/5,1/21/1, 5/6, 5/5,1/2

* According to ASHRAE 52.1 – 1992

 

Depth-loading filter cartridges TFP 60 and TFP 90

UnitTFP60TFP90
Filtering areaft2 (m2)33 (3) 120 (11)
Thermal stability°F (ºC)158°F (70°C)
Peaks to 176°F (80°C)
158°F (70°C)
Peaks to 176°F (80°C)
Moisture resistance%100100
Average arrestance%99100
Average efficiency%6596
Nominal volume flow rateft3/m (m3/h))600 (1000)600 (1000)
Initial pressure dropin. H2O (Pa)0.44 (108)0.44 (109)
Recommended final
pressure drop
in. H2O (Pa)3.2 (800)3.2 (800)
Dust holding capacity*
(ISO Fine / 3.2 in. H2O, 800 Pa)
oz (g)81 (2300)42 (1200)

MX

MX75MX85MX95MX98MX100
Rated Air Flow (cfm)20002000200020002000
Average Dust Spot
Efficiency (%)*
75859598
DOP Efficiency (5)96
Initial Efficiency on
Particles >1 micron (%)
>87>95>97>99>99.8
Initial Resistance
(in. w.g.)
0.300.340.400.460.80
Burst Strength (in. w.g.)
Max. Temperature (ºF)160,
peaks 200
160,
peaks 200
160,
peaks 200
160,
peaks 200
160,
peaks 200
UL 900 Classification
Depth (in)11.511.511.511.511.5
Size Availability1/1, 5/6,1/21/1, 5/6,1/21/1, 5/6,1/21/1, 5/6,1/21/1, 5/6,1/2

* According to ASHRAE 52.1 – 1992

Mini Pleat Filters

Mini75-2/44Mini85-2/44Mini95-2/44Mini75-4/44Mini85-4/44Mini95-4/44
Rated Air Flow (cfm)200020002000200020002000
Average Dust Spot
Efficiency (%)*
758595758595
Initial Efficiency on
Particles >1 micron (%)
>80>91>94>80>91>94
Initial Resistance
(in. w.g.)
0.250.430.480.200.380.44
Max. Temperature (ºF)160,
peaks 175
160,
peaks 175
160,
peaks 175
160,
peaks 175
160,
peaks 175
160,
peaks 175
UL 900 ClassificationClass  2Class  2Class  2Class  2Class  2Class  2
Depth (in)222444
Size AvailabilityAll standard sizesAll standard sizesAll standard sizesAll standard sizesAll standard sizesAll standard sizes

* According to ASHRAE 52.1 – 1992

TFP Cartridges

MV65MV75MV85MV95
Rated Air Flow (cfm)2000200020002000
Average Dust Spot Efficiency (%)*65758595
Initial Efficiency on Particles >1 micron
(%)
>69>80>91>94
Initial Resistance
(in. w.g.)
0.260.270.290.33
Max. Temperature
(ºF)
160,
peaks 175
160,
peaks 175
160,
peaks 175
160,
peaks 175
UL 900 ClassificationClass 2Class 2Class 2Class 2
Depth (in)11.511.511.511.5
Size Availability1/1, 5/6, 5/5,1/21/1, 5/6, 5/5,1/21/1, 5/6, 5/5,1/21/1, 5/6, 5/5,1/2

* According to ASHRAE 52.1 – 1992

 

Depth-loading filter cartridges TFP 60 and TFP 90

UnitTFP60TFP90
Filtering areaft2 (m2)33 (3) 120 (11)
Thermal stability°F (ºC)158°F (70°C)
Peaks to 176°F (80°C)
158°F (70°C)
Peaks to 176°F (80°C)
Moisture resistance%100100
Average arrestance%99100
Average efficiency%6596
Nominal volume flow rateft3/m (m3/h))600 (1000)600 (1000)
Initial pressure dropin. H2O (Pa)0.44 (108)0.44 (109)
Recommended final
pressure drop
in. H2O (Pa)3.2 (800)3.2 (800)
Dust holding capacity*
(ISO Fine / 3.2 in. H2O, 800 Pa)
oz (g)81 (2300)42 (1200)